Quality control and parameters measurement system for IVG-type relays |
|
The relay parameters control device is intended for automatic and hand-operated measurements and control of ralay parameters on conformity to the technical requirements to parameters of relay IVG, IVG-M, IVG-B - types, used in railway automatics systems. |
![]() |
The relay parameters control device is carried out portable. Relay connection with the UKPR makes througth relay sockets, located on face and back sides of the device. For indication of operational mode and values of measuring parameters used liquid crystal indicator. Joint work of the device with IBM PC is available througth RS-232 channel .
The relay parameters control device provides: |
|
|
Measurement of effective voltage of operation and release of the relay in alternating current in a range of from (0,010..4,095) V. |
|
Calculation of a difference between latch and unlatch voltage of front(rear) contact at operation (release) of relay. |
|
Measurement of contact resistance of common - front, common - rear contacts in a range of (0,02..1,00) ohm. |
|
Measurement of relay operation and release time in a range of (0,1..150) ms. |
|
Measurement of bridge strapping and common contact switch time intervals at relay operation and release in a range of (0,1..20) ms. |
|
Calculation of a difference between maximum and minimum of operation time at work in a pulsed mode. |
|
Measurement of resistance of the heating resistor in a range of (10..2000) ohm. |
|
Check of relay contacts' chatter absence at increase of voltage on relay winding from 0 up to 40 V during 2 seconds and during 10 ms. |
|
Check of RCD-circuit for open citcuit and short circuit. |
|
Check of relay work in a pulsed mode at nominal load 1A. |
|
The control of reed relay integrity and air-tightness. |
![]()